Mac 250 Krypton User Manual

MAC 250 Krypton Martin does not supply exploded diagrams for their fixtures. If you are in need of assistance finding a part number, or cannot locate your parts in the list below, contact us and we will be happy to assist you. According to the user notes in the ETC Fixture Release Notes for the MAC 250 Krypton: Ch 1 DMX 208,217 - Set Menu option dRES to 5 Seconds for this personality. Ch 1 DMX 248,255 - Set Menu option dLOF to ON for this personality. 6 MAC 250 Krypton SETUP Unpacking The MAC 250 Krypton comes with:. MSD 250/2 lamp (not installed). 3-meter, 3-wire IEC power cable. user manual. 1/4-turn clamp mounting bracket. 5-meter, 3-pin shielded XLR control cable The packing material is carefully designed to protect the fixture during shipment - always use it or a custom flight case to transport the fixture. Diplotop - product comparison - gathers MARTIN MAC 250 KRYPTON users reviews, tests and opinions.With a data base of unprecedented wealth, 76 reviews for the MARTIN MAC 250 KRYPTON, Diplotop compares the MARTIN MAC 250 KRYPTON with its competitors in order to find the best.

4 MAC 250 Krypton INTRODUCTION Thank you for selecting the Martin MAC 250 Krypton. Features Some of the many features include: • efficient, 2000 hour, 250 watt discharge lamp • 12 interchangeable dichroic colors • 7 interchangeable indexed-rotation gobos • interchangeable 3-facet rotating prism • motorized focus • full-range dimming • fast blackout and strobe effects • coated optics • user-installable firmware • switch-selectable power supply settings For the latest firmware updates, documentation, and other information about this and all Martin Professional products, please visit the Martin web site at http://www.martin.dk.

Mac

About this manual This manual is preliminary and describes the specified functionality. Some of the described features are not present in the initial release of the MAC 250 Krypton software. Please check the Martin web site at http://www.martin.dk for the latest product software and documentation. Comments or suggestions regarding this document may be e-mailed to service@martin.dk or posted to Martin Professional A/S Olof Palmes Allé 18 DK-8200 Aarhus N, Denmark Attn: Service Department Please review the important safety precautions in this manual before installing and operating the fixture.

MAC 250 Krypton safety information Warning! This product is for professional use only. It is not for household or residential use. This product presents risks of lethal or severe injury due to fire and heat, electric shock, ultraviolet radiation, lamp explosion, and falls. Read this manual before powering or installing the fixture, follow the safety precautions listed below and observe all warnings in this manual and printed on the fixture. If you have questions about how to operate the fixture safely, please contact your Martin dealer or call the Martin 24-hour service hot line at +45 70 200 201.

Mac 250 Entour

MARTIN MAC 250 KRYPTON/ENTOUR USER MANUAL NEW IN GERMAN in Musical Instruments & Gear, Stage Lighting & Effects, Other. PopScreen - Video Search, Bookmarking and Discovery Engine. Martin Mac 250 Krypton Entour User Manual New in German. Item discovered at ebay.com; See more similar items →. This case was specifically made to fit an MARTIN MAC 250 KRYPTON moving head. The case is constructed of 1/4' plywood with a heavy weight black vinyl laminate surrounded in aluminum extrusion and permanently machine split riveted together.

P R O T E C T I O N F R O M E L E C T R I C S H O C K Warning! Always disconnect from mains supply before replacing the lamp. • Disconnect the fixture from AC power before removing or installing the lamp, fuses, or any part, and when not in use. • Always ground (earth) the fixture electrically.

Mac 250 Krypton User Manual Download

InstallationLOCATION AND ORIENTATIONThe MAC 250 Krypton/Entour may be installed in any orientation. It can be fastened directly to a suitable surface, hung with a rigging clamp, or placed directly on a level surface. For safe operation, install the MAC 250 Krypton/Entour in a location where: · · · · the fixture is at least 1 meters (39 inches) away from combustible materials the fixture is protected from rain and moisture there is at least 0. 1 meters (4 inches) clearance around the fan and control panel there are no flammable materials nearbyRIGGING OR MOUNTING THE MAC 250 KRYPTON/ENTOURWarning! Block access below the work area before proceeding. The MAC 250 Krypton/Entour can be placed on stage or clamped to a truss in any orientation. The Fast-Lock system enables quick and easy fastening of the clamp brackets in 4 positions. 8MAC 250 Krypton/EntourThe MAC 250 Krypton/Entour includes an omega clamp mounting bracket to which 1 or 2 rigging clamps (not included) can be bolted. The clamp mounting bracket fastens to the base as shown with 1/4-turn fasteners. Figure 2: Clamp mounting bracket Warning! Attach an approved safety cable to the attachment point provided in the base. Never use the carrying handles for secondary attachment. Always use an approved safety cable. The 1/4-turn fasteners are locked only when turned fully clockwise. Verify that the clamps are in good condition and can bear at least 10 times the weight of the fixture. Bolt clamps to the bracket with a grade 8. 8 (minimum) M12 bolt and lock nut, or as recommended by the clamp manufacturer, through the 13 mm holes in the clamp mounting bracket. Align the clamp mounting bracket with any 2 key slots on the base. Insert both locking pins into the slots and turn both levers a full 1/4 turn clockwise to lock...